AMC16Z-FAK48 Multi Channel Din Rail Ac Power Meter


● Designed specifically for the power supply management of server in the data center


● A+B independent 24 circuits(48 in total)


● U, I, P, Q, S, PF, kWh, kvarh


● 2nd-31st  Harmonic


● kWh Class 0.5


● DIN 35 mm

  • Overview
  • Parameter
  • Certificates
  • Customer Questions & Answers
  • Contact us

Application

2

1.Enterprise Data Centers  2.Large Data Center IDC 3. Network Room  4.Data Service Data Room


Overview

Data center rapid development, data center energy consumption problems are becoming more and more prominent, data center energy management and power supply and distribution design has become a hot issue, efficient and reliable data center power distribution system program, is to improve the data center power efficiency, reduce equipment energy consumption effective way. AMC series data room precision power distribution monitoring device is a complete solution designed for the light distribution monitoring requirements of data center column cabinets.


image


Specific model: AMC16Z-FAK48

Technical requirements: input phase voltage AC220V; The incoming line current AC 5A conversion ratio is self-set; Outlet current conversion ratio AC100A/20mA; 


2-way incoming line detection; 36-channel single-phase (or 12-way three-phase) outlet detection; 1 switching output.

Communication protocol: RS485 interface Modbus/RTU protocol

Auxiliary power supply: AC220V


Function

AMC series data room precision power distribution monitoring device product design is small, adapt to the characteristics of data center load loops, realize the high integration of monitoring loops, and can accurately monitor each AC or DC load in the data center.


Wiring


5-4

Network



5-5


5-6

AC Network Solution


5-7

DC Network Solution


Product Selection

Product ShapeDevice NameModelMain Features

image

HMI touch screen

ATP007kt

ATP010kt

7 inch / 10 inch touch screen, real-time monitoring and display of precision power distribution unit voltage, current, power, power supply, power quality, switching status, waveform curve, etc., can also monitor the module alarm communication and other parameters configuration, 2 RS485, 1 channel Ethernet interface, can be monitored through the transmission ring on the interface.

image

AC incoming monitoring module


AMC16Z-ZA

DIN rail installation, measuring the power parameters of the isolated two three-phase circuits, 6DI2D0, 2 leakage, 1 temperature and humidity measurement, with DC24V output to give line module and touch screen power supply; Support RS485 communication (Modbus protocol).

image

AC outlet monitoring module

AMC16Z-FAK24

AMC16ZFAK48

Din rail installation, maximum measurement of 16 three-phase or 48 single-phase AC circuit power parameters, DC24V power supply (can be powered by the incoming module); Support RS485 communication (Modbus protocol).

image

AC outlet instrument transformerAKH-0.66W

Current conversion ratio: 100A/50mA

Universal: 100A/50mA

image

DC incoming line monitoring module

AMC16Z-ZD


DIN rail installation, measuring the power parameters of the isolated two DC circuits, 6DI2DO, 1 way temperature and humidity measurement, with DC24V output to give line module and touch screen power supply; Support RS485 communication (Modbus protocol).

image

DC outlet monitoring module


AMC16Z-FDK24

AMC16Z-FDK48

Din rail installation, maximum measurement of power parameters of 48 DC circuits out, DC24V power supply (can be powered by the incoming module); Support RS485 communication (Modbus protocol).

image

DC incoming insulation monitoring module

AMC16Z-ZJY

Din rail installation, measuring the positive and negative busbar insulation resistance of the two isolated DC circuits, DC24V power supply (can be powered by the incoming module); Support RS485 communication (Modbus protocol).

image

DC outlet insulation monitoring moduleAMC16Z-FJYDin rail installation, measuring the positive and negative bus insulation resistance of 24 DC circuits out of the line, DC24V power supply (can be powered by the incoming module); Support RS485 communication (Modbus protocol).

image

DC outlet Hall sensorAHKC-BS

Current conversion ratio: 100A/5V

Universal: 100A/5V


Technical parametersAMC16Z-FAK24AMC16Z-FAK48
Measurement parameters
Voltage, current, frequency, active power, reactive power, power factor, active
power, reactive power, switching state
2-31 times harmonics
Bus VoltageRated220VAC

Measurement±20%
OverloadInstantaneous voltage 2 times/second
Current
outgoing line loop
Rated50mA
Range0.125~60mA
OverloadDuration 1.2 times, instantaneous 10 times/second
Input frequency
45~60Hz
Measurement accuracyOutgoing lineVoltage/current/active power/active energy level 0.5, reactive power/reactive energy level 1
Auxiliary power supply
Power supply by AMC16Z-ZA
EnvironmentTemperatureWorking:-15℃~55℃ Storage:-25℃~70℃
HumidityRelative humidity
Altitude≤2500m
Communication
RS485/Modbus-RTU
Installation method
DIN35mm Guide rail or bottom plate mounting
IP grade
IP20
Class of pollution
2
SafetyInsulationAll terminals and the insulation resistance between the conductive pieces not below 100 m Ω

Withstand voltageA-channel voltage and current signal // B-channel voltage and current signal // other ports meet AC2kV 1min between pairs, leakage current should be less than 2mA, no breakdown or flashover phenomenon.
Electromagne
tic
compatibility
Anti static interferenceLevel 4

Resistance to
radiation of
Radio frequency
electromagneti
Level 3


Customer Questions & Answers
  • Question:

    Who are we?

    Answer:

    We are a top manufacturer with over 1500 employees, over 300 R&D engineers in China, with CE, ROHS, IEC, EAC, MID, UL, FCC Certificates, etc. Our Products: AC/DC electricity meters, current transformers, hall sensors, IOT platform, etc. As a top-level provider of electrical solution service, we can help you save energy, reduce cost, improve energy efficiency and safety, realize intelligent, visual and fine management of energy, and provide data services for energy management.

    marry August 16, 2022
  • Answer:

    Always a pre-production sample before mass production; Always final Inspection before shipment;

    marry August 16, 2022
  • Answer:

    AC/DC Energy Meter, Hall Effect Sensor, Current Transformer, Current Transducer, Motor Protectors, Wireless Temperature, Monitoring, Residual Current Relay, IOT Platform, etc.

    marry August 20, 2022
  • Answer:

    147 computer software copyrights, 2 million meters, 1.5 million transformers, more than 100 design patents, 70 utility model patents.

    marry August 16, 2022
  • Answer:

    Accepted Delivery Terms: FOB, CFR, CIF, EXW, DDU, Express Delivery, etc. Accepted Payment Currency: USD, EUR, RMB, etc. Accepted Payment Type: T/T, L/C, etc. Language Spoken:English, Spanish, Chinese, etc.

    marry August 16, 2022
Your Name
E-mail *
Phone/Whatsapp
Country
Your identity (dealer or individual)
Your Inquiry *
Clicky