ADW210 IoT Din Rail Mounted Multi-Channel Energy Meter


● Mearsure up to 4 circuit 3 phase


● Mearsure all electric parameters


● Split core open loop CTs


● External function module, such as MK(switching inputs and outputs), MTL(temperature measurement and leakage current measurement), AWT100(wireless communication)


● LCD Display

  • Overview
  • Parameter
  • Certificates
  • Customer Questions & Answers
  • Contact us

ADW210 series multi-loop power meter is mainly used for the measurement of all electric parameters of three-phase circuit. Colleagues can select the current input of the maximum four circuits. ADW2XX series products are connected by split core current transformer, easy to install on site, and realize remote wireless communication through wireless communication module.


Function


1

Accuracy
Active power: Class 1
Reactive power: Class 2


Frequency
Range: 50 - 60Hz

Pulse output
Active pulse output and reactive pulse output

Consumption
<0.5VA(Single phase)

Dimension (L*W*H)
Panel size (L×W): 72*97.7*36 mm

Installation:Din 35mm

Wireless
Transmission on 470MHz and maximum distance
in open space is 1km; 2G; NB


Starting current:4‰lb

2


Optional Module



3-3


External Module (MTL)
12 External NTC Temp. Measurement
4 Channels Residual Current Measurement


3-4


External Wireless Module(AWT100)
Downlink RS485; Uplink 4G, 2G, NB, Lora, LoraWAN, Ethernet, WiFi, GPS, Profibus


3-5


External Module(MK)
12 Channels DI + 4 Channels DO


Dimension

3-6


Main part dimension(L×W×H): 87.8*72*71.5mm
35mm Din rail installation; Tolerance: ±1mm


3-7


Module dimension(L×W×H): 87.8*36*71.5mm
35mm Din rail installation; Tolerance: ±1mm


Current TransformerMatched with ADW2xx SeriesDimension(mm)Perforation size (mm)
WHDMNφ1φ2
AKH-0.66/K-∅ 10N2744322536109
AKH-0.66/K-∅ 16N31503627421617
AKH-0.66/K-∅ 24N39714636522423.5
AKH-0.66/K-∅ 36N42.5825840563635
Picture of Current Transformer3-8


Installation

3-9

① Main Body of ADW2xx;

② External Module 1(MTL/MK);

③ AWT100-*(NB/2G/4G/Lora/LW Communication)

3-10


Wiring

3-11


① U / Pulse / DO / DI / Communication / Auxiliary Power Supply
② Brand
③ Panel
④ Model Number
⑤ CH1, CH2, CH3, CH4 for current / extension module interface
⑥ Button
⑦ Infrared Status
⑧ Pulse Output Light

3-12

Network


3-13


3-14

Package


MINIMUM PACKAGE3-153-16
MINIMUM PACKAGEPackage Dimension(1 PC)
170*150*130mm
WHOLE BOX PACKAGEPackage Dimension(36 PCS)
540*530*480mm


MINIMUM PACKAGE3-173-18
MINIMUM PACKAGEPackage Weight(1 PC)
0.245Kg
WHOLE BOX PACKAGEPackage Weight(36 PCS)
10.5kG


ATTENTION !
The above packing and weight data are only refer to model ADW210.
For other models or optional functions, please contact the salesman for details, thank you for your cooperation!


Auxiliary power
AC/DC 85~265V; Consumption≤10VA;
InputFrequency45~65Hz;
VoltageAC 3×220V/380V; Overload: 1.2 times of rated value (continuous);2 times of rated value / 1s; Power consumption: ≤ 0.5VA;
CurrentAC 5A、100A、400A、600A;(External opening transformer); Power consumption: ≤ 0.5VA;Overload: 1.2 times of rated value (continuous); 10 times of rated value / 1s;
Measurement accuracy
Frequency 0.05Hz, voltage、current Class 0.5; 2-31st harmonic accuracy: ± 1%;Active electric energy level 1, reactive electric energy level 2;
FeaturesPulse outputOutput mode: optocoupler pulse with open collector;
CommunicationRS485、Modbus-RTU; Baud rate 1200~38400;
Switching InputDry contact input、Built in power supply;
Switching OutputOutput mode: Relay normally open contact output; contact rating: AC 250V/3A DC 30V/3A;



Customer Questions & Answers
  • Question:

    Who are we?

    Answer:

    We are a top manufacturer with over 1500 employees, over 300 R&D engineers in China, with CE, ROHS, IEC, EAC, MID, UL, FCC Certificates, etc. Our Products: AC/DC electricity meters, current transformers, hall sensors, IOT platform, etc. As a top-level provider of electrical solution service, we can help you save energy, reduce cost, improve energy efficiency and safety, realize intelligent, visual and fine management of energy, and provide data services for energy management.

    marry August 16, 2022
  • Answer:

    Always a pre-production sample before mass production; Always final Inspection before shipment;

    marry August 16, 2022
  • Answer:

    AC/DC Energy Meter, Hall Effect Sensor, Current Transformer, Current Transducer, Motor Protectors, Wireless Temperature Monitoring, Residual Current Relay, IOT Platform, etc.

    marry August 20, 2022
  • Answer:

    147 computer software copyrights, 2 million meters, 1.5 million transformers, more than 100 design patents, 70 utility model patents.

    marry August 16, 2022
  • Answer:

    Accepted Delivery Terms: FOB, CFR, CIF, EXW, DDU, Express Delivery, etc. Accepted Payment Currency: USD, EUR, RMB, etc. Accepted Payment Type: T/T, L/C, etc. Language Spoken:English, Spanish, Chinese, etc.

    marry August 16, 2022
Your Name
E-mail *
Phone/Whatsapp
Country
Your identity (dealer or individual)
Your Inquiry *
Clicky