All Categories
EN

Home > Products > Energy Meter > AC Energy Meter

MID Support ADL400 Three-Phase Din Rail Energy Meter


● Rated Current: 1 (6) A, 10 (80) A


● Rated Voltage: AC220V/380V, AC230V/400V


● RS485(MODBUS-RTU) Communication


● 12 digits LCD Display; 35mm DIN Rail Installation


● 2~31st Harmonic Measurement


● kWh Class 0.5S

  • Overview
  • Parameter
  • Certificates
  • Customer Questions & Answers
  • Contact us

ADL400 din rail energy meter adopts DIN35mm din rail installation with LCD display,it can measure electric parameters and has energy pulse output, RS485 communication,which has the advantages of small size, high precision, good reliability and convenient installation.


1

① Voltage Enter-wire
② Brand
③ Panel
④ Up Button
⑤ Down Button
⑥ Auxiliary function
⑦ Pulse Output
⑧ Model
⑨ Set Button
⑩ CT Enter-wire



Functions



2

3

Display


4



Wiring



5




projectperformance parameter
Specification3 phase 3 wires, 3 phase 4 wires
MeasurementVoltageReference voltage3×100V、 3×380V、3×57.7/100V、 3×220/380V
Consumption<10VA(Single phase)
Impedance>2MΩ
Accuracy classError±0.2%
CurrentInput current3×1(6)A, 3×10(80)A
Consumption<1VA Single phase rated current
Accuracy classError±0.2%
PowerActive, reactive, apparent power, error±0.5℅
Frequency45~65Hz,Error±0.2%
MeteringEnergyActive energy(Accuracy class: 0.5) reactive energy(Accuracy class 2)
Clock≤0.5s/d
Digit signalEnergy pulse output1 active photocoupler output
pulseWidth of pulse80±20ms
Pulse constant400imp/kWh,10000imp/kWh(Correspond with the basic current)
communicationInterface and communication protocolRS485口:Modbus RTURS485:Modbus RTU
Range of communication addressModbus RTU:1~ 247;
Baud rate1200bps~19200bps
environmentworking temperature-25℃~+55℃
Relative humidity≤95℅(No condensation)




Customer Questions & Answers
  • Answer:

    Switch the meter display to the power (active power P, power factor λ) interface, and check whether the power display is negative or not. And whether the power factor is between 0.9-0.95, and then check whether the incoming and outgoing wires of the current signal wire are connected reversely (that is, the current The incoming wire must be the same as the incoming wire end of the instrument) and consistent with the wiring diagram on the instrument.

    marry August 31, 2022
  • Answer:

    1. The voltage value between the communication output A and B of the measuring instrument should be between +(4.4-4.5)V; 2. Check whether the communication wiring method is correctly wired in accordance with the wiring diagram requirements (that is, the communication terminal A/B of the corresponding to communication serial port A/B);

    marry August 31, 2022
Your Name
E-mail *
Phone/Whatsapp
Country
Your identity (dealer or individual)
Your Inquiry *
Clicky