APM810 AC Multifunction Meter


Optional Communication:Modbus-Tcp(Ethernet),Profibus-DP Communication,Modbus-RTU


Power Supply:AC/DC 85-265V


● THD with 63rd Harmonics


● K-Factor and Crest Factor


● Unbalance & Phase Angles


● Demands and Multi-Tariff energy


● Max/Min Log with Timestamp


● Harmonic: 1%(2~42nd), 2%(43~63rd)


● Accuracy: 0.5s

Email: [email protected]

Mobile: +86 134 8217 7205

Whatsapp/Wechat: +86 134 8217 7205

  • Overview
  • Parameter
  • Certificates
  • Customer Questions & Answers
  • Contact us


Applicaion


image



Mining

Petrochemical

Municipal Project

Transportation


Building 

Hotel

Hospital

Electric Safety



















Overview

APM810 Panel Multifunction Smart Meter have full power measurement, energy statistics, analysis of power quality and network communications and other functions, are mainly used for comprehensive monitoring of the quality of power supply network.

Our APM series meters are suitable for the measurement and display of grid electricity. Active energy measurement accuracy meets the 0.5S level required by IEC62053-22. The APM series of meters provide many high-performance features required to measure and monitor electrical installations. All models are configured with an RS-485 Modbus communication port, two digital inputs, two digital outputs, and critical condition alarms.


Function

image


Dimension

image

Display


6-4


Installation


image

① Cut out a 92*92mm hole on the panel. (If not existed)

image

② Unleash all the static, move off installation  terminal, put in the panel.

image

③ Fixed the meter on panel by using the incidental brackets with buckle.

image

④ Installation complete.

Wiring

image

Low Voltage 3 Phase 4 Wire

image

High Voltage 3 Phase 3 Wire


Network


6-6

More Products Recommend

ShapeModelFunctionOptional Function

image

APM800

( Class 0.5S)

3-phase(I,U,kW,kVar,kWh,kVarh,Hz,cosφ);zero-sequence current In;

4-quadrant energy;real-time & max demand;extremum of this month and last month;current & voltage unbalance; load current histogram;

66 types of alarm and 16 pcs of SOE;support SD card expansion ;2DI+DO;RS485/MODBUS;LCD display

1.Multi-rate(F)


2.8DI+2DO(MD82)


3.SD Card (MLOG)


4.8AI+4AO(MA84)


5.RS485(MCM)


6.Ethernet(MCE)


7.Profibus-DP(MCP)

APM801

( Class 0.2S)

3-phase(I,U,kW,kVar,kWh,kVarh,Hz,cosφ);zero-sequence current In;

4-quadrant energy;real-time & max demand;extremum of this month and last month;current & voltage unbalance; load current histogram;

66 types of alarm and 16 pcs of SOE;support SD card expansion ;2DI+DO;RS485/MODBUS;LCD display

APM810

( Class 0.5S)

3-phase(I,U,kW,kVar,kWh,kVarh,Hz,cosφ);zero-sequence current In;

4-quadrant energy;real-time & max demand;extremum of this month and last month;current & voltage unbalance; load current histogram;66 types of alarm and 16 pcs of SOE;support SD card expansion ;2DI+DO;RS485/MODBUS;

2~63st harmonic ;LCD display

APM810

( Class 0.2S)

3-phase(I,U,kW,kVar,kWh,kVarh,Hz,cosφ);average;extremum;

fundamental current;fundamental voltage;demand;multi-rate/tariff;

current & voltage unbalance;4-quadrant energy;multi-rate energy;THD;

odd & even harmonic;vector;alarm record;SOE;wave record;transient 

record;2DI+2DO;RS485/MODBUS(support data frozen );digits LCD display

1.8DI+2DO(MD82)

2.SD Card (MLOG)


3.8AI+4AO(MA84)


4.RS485(MCM)


5.Ethernet(MCE)


6.Profibus-DP(MCP)


Technical ParametersIndex
SignalElectrical networkThree-phase three-wire, three-phase four-wire, see the wiring diagram;
Frequency45~65Hz;
VoltageRated value:AC 100V、110V、400V、690V;
Overload: 1.2 times rated value(continuous); 2 times rated value /1 second;
Power consumption: < 0.5VA (per channel);
CurrentRated value: AC 1A, 5A, support 4 mm2 line access;
Overload: 1.2 times rated value(continuous); 10 times rated value/1 second;
Power consumption: < 0.5VA (per channel);
Measurement accuracyVoltage、current and powerclass 0.5s/class 0.2s (APM800、APM810/APM801)
Active powerclass 0.5s/class 0.2s (APM800、APM810/APM801)
Reactive powerclass 2
Harmonic1%(2rd~42nd)、2%(43rd~63rd)
Switch inputsDry contact inputs, built-in power supply;
Relay outputsContact type: open contact in main part, changeover contact in module;Contact capacity:AC 250V/3A  DC 30V/3A;
Pulse output of energyOutput mode: Optocoupler pulse with open collector;Pulse constant:4000(5A)、8000(1A) imp/kWh;
Analog outputsDC 0mA~20mA、4mA~20mA、0V~5V、1V~5V output, accuracy class 0.5%, load resistance ≤ 500Ω;
Analog inputsDC 0mA~20mA、4mA~20mA、0V~5V、1V~5V iutput, accuracy class 0.5%
Storage cardStandard Capacity:4G,TF Card Up to 32G Capacity;
CommunicationRS485 interface/Modbus-RTU protocol and DLT645 protocolProfibus-DP interface/Profibus-DP protocol;RJ45 interface (Ethernet) / Modbus-TCP, http, DHCP and other protocols;
Power supplyWorking range: AC/DC 85V~265V or AC/DC 115~415V(P2);Power consumption: Power consumption of the main part ≤ 15VA;
SafetyPower frequency withstand voltageThe power frequency withstand voltage between the shell and the auxiliary power supply, each input and output terminal group is AC 4kV/1min;The power frequency withstand voltage between the auxiliary power supply and each input and each output terminal group is AC 2kV/1min;The power frequency withstand voltage between the voltage input and other input/output terminal groups is AC 2kV/1min;The power frequency withstand voltage between the current input and other input/output terminal groups is AC 2kV/1min;The power frequency withstand voltage between the relay output and other input/output terminal groups is AC 2kV/1min;The power frequency withstand voltage between each terminal group of switch input, communication, analog output and pulse output is AC 1kV/1min;
Insulation resistanceInputs、outputs to the shell>100MΩ;
Electromagnetic compatibilityMeet IEC 61000 standard (Level 4);
Protection levelDisplay panel IP52
EnvironmentOperating temperature: -20 °C ~ +65 °C;Storage temperature: -20°C~+70°C;Relative humidity: ≤95% without condensation;Altitude: ≤2500m;
StandardsIEC 60068-2-1IEC 60068-2-2IEC 60068-2-30Environmental Testing-Part 2-1:Tests Test A:Cold IDAPart 2-1:Tests Test B:Dry heatPart 2-30:Tests Test Db:Damp heat,cyclic(12+12h)
IEC 61000-4Electromagnetic compatibility-Testing and measurement techniques
IEC 61557-12Electrical safety in low voltage distribution system up to 1000V a.c. and1500V d.c –Equipment for testing,measuring or monitoring of protective measures- Part12:Performances measuring and monitoring devices(PMD)
IEC 62053-22Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2s and 0.5s)