Acrel DTSD1352/C 3 Phase Power Meter for Solar System
● IEC62053-21、IEC62053-22
● Din rail mounted
● kWh: Class 0.5S,kVarh:Class 2
● AC 3×220/380V,3×380V,3×57.7/100V,3×100V
● 3×1(6)A,3×10(80)A
● U、I、P、Q、S、PF、kWh、kvarh
● RS485(MODBUS-RTU)
- Overview
- Parameter
- Certificates
- Customer Questions & Answers
- Contact us
DTSD1352/C also called ADL3000-E is a smart meter designed for power supply system, industrial and mining enterprises and utilities to calculate the electricity consumption and manage the electric demand. It features the high precision, small size and simple installation. DTSD1352 can be used in all kinds of control systems, SCADA systems and energy management systems. All meters meet the related technical requirements of electronic power meter in the IEC62053-21、IEC62053-22 standards.
① Seal for Anti theft
② Brand
③ Panel
④ Enter-wire
⑤ Auxiliary function
⑥ Pulse output light
⑦ Button
⑧ Outlet wire
Functions
Communication
RS485(Modbus-RTU)
Rated U and I
AC 3×100V, 3×380V, 3×57.7/100V, 3×220/380V; 3×1(6)A, 3×10(80)A
Accuracy
kWh: Class 0.5S,kVarh:Class 2
Frequency
50/60HZ(Optional),range: 45~65HZ
Display
8 digits LCD display U, I, P, Q, PF, kWh and other energy consumption, Power measure (999999.99kWh)
Pulse output
Pulse output kWh/kvarh
Consumption
<10VA(Single phase)
Installation
DIN 35mm
Dimension(L*W*H)
126.5*88*69.5mm
Switch relay
Magnetic latching relay(ADL3000-E build-in)
Clock
≤0.5s/d
Starting current
Direct connect: 0.004Ib
Connect via CT: 0.001In
Wiring
Dimension & Installation
Package
PACKAGE PHOTOS | ||
MINIMUM PACKAGE | Package dimensions(1 PC) 170*150*130mm | |
MINIMUM PACKAGE | Net Weight(1 PC) 0.254KG |
ATTENTION !
The above packing and weight data are only refer to model ADL3000-E.
For other models or optional functions, please contact the salesman for details, thank you for your cooperation!
Voltage | Reference voltage | 3×220/380V,3×380V,3×57.7V/100V,3×100V,3×380/660V,3×660V |
Reference Frequency | 50Hz | |
Consumption | <2VA(Single phase) | |
Current | Input current | Outlay transformer:3×1.5(6)A、3×20(100)AInlay transformer:3×1.5(6)A |
Starting current | Outlay transformer:1‰Ib(3×1.5(6)A)、4‰Ib(3×20(100)A)Inlay transformer:1‰Ib | |
Consumption | <1VA (Maximum current) | |
Measure performance | Conform to the standard | GB/T 17215.321-2008 GB/T 17215.322-2008 GB/T 17215.323-2008 |
Accuracy class | Outlay transformer:Active energy(Accuracy class:0.5s), reactive energy(Accuracy class 2)(3×1.5(6)A)Active energy(Accuracy class:1), reactive energy(Accuracy class 2)(3×20(100)A)Inlay transformer:Active energy(Accuracy class:0.5s), reactive energy(Accuracy class 2) | |
The clock precision | ≤0.5s/d | |
pulse | The pulse width | 80ms±20ms |
Pulse constant | Outlay transformer:6400imp/kWh(3×1.5(6)A)400imp/kWh(3×20(100)A)Inlay transformer:6400imp/kWh | |
Communication | interface | RS485(A+、B-) |
medium | Shielded twisted pair | |
agreement | MODBUS-RTU |
Customer Questions & Answers
-
Answer:
Yes, press the key to set the meter to three-phase three-wire mode.
marry August 30, 2022 -
Question:
What is the difference between ordinary secondary access and -CT (model external transformer)?
Answer:Ordinary secondary meter could access the ratio XXX/5(1)A of the CTs which could be actual current on site, the -CT model comes with an external transformer will be convenient for installation(It cannot be disassembled, otherwise it will burn the meter). There are CTs available on site to facilitate with No stitch removal.
marry August 30, 2022 -
Answer:
3*100V, 3*57.7/100V are used for high voltage, used in conjunction with voltage transformers, where 3*100V represents 3P3W,3*57.7V/100V represents 3P4W; 3*380V, 3*220V/380V are used for low voltage, direct voltage input, among them3*380V represents 3P3W, 3*220V/380V represents 3P4W.
marry August 30, 2022 -
Question:
Can this meter communicate with PLC?
Answer:Yes, only need PLC to support RS485 interface, Modbus RTU or DL/T645 protocol.
marry August 30, 2022