UL Certificate AGF-AE-D series 1 phase 3 wires Energy Meter for solar inverter
●Single phase three wire power meter
●Application: inverters in Australia, Europe, North America and other areas
●Rated voltage: AC 120V/208V,240V(88%~110%)
●Rated current: AC 100A ,200A(Configure transformer)
- Overview
- Parameter
- Certificates
- Customer Questions & Answers
- Contact us
Overview
At present, grid companies usually require photovoltaic grid-connected systems to be non-reverse current power generation systems, that is, the electricity generated by photovoltaic grid-connected systems is consumed by local loads, and excess electricity is not allowed to be reversely transmitted to the upper grid through low-voltage distribution transformers. In the grid-connected power generation system, because the external environment is constantly changing, in order to prevent reverse power generation of the photovoltaic grid-connected system, the system needs to perform reverse current detection, and adjust the power generation of the system by monitoring the voltage and current signals on the low-voltage outlet side of the distribution transformer in real time , so as to achieve the anti-backflow function of the photovoltaic grid-connected system.
In a single inverter system, the meter is connected directly to the inverter. If your inverter has a built-in revenue grade meter (RGM; the inverter is referred to a revenue grade inverter), you can connect an external meter on the same bus as the RGM.
| ① Brand / Model ② Panel ③ Indictor Lights ④ Reset Button ⑤ Current Transformer |
Product Data
| Parameters | AGF - AE - D /100 | AGF - AE - D /200 |
| Meter Electrical Service | ||
Rated Voltage - Line to N | 120V | |
| Rated Voltage - Line to Line | 208/240V | |
| Extended Voltage Range | 88%-110% | |
| AC Frequrency | 60Hz | |
| Grids Supported | L1/L2/N/ PE | |
| Power Consumption | 1.2w | |
| communication | ||
| Meter communication interfaces | RS485 | |
| Response Time | ≤1S | |
| Meter Accuracy | ||
| Rated RMS current | 100A | 200A |
| 1%-100% of CT Current | 土0.5% | 土1% |
| Current Transformers | ||
| Number of Supplied Current Transformers | 2 | |
| Dimensions | I . D :15 O . D :35 | 70.5x54.5x39( HxWxD ) mm |
| Standard compliance | ||
| Safety | UL1741 | |
| Installation Specifications | ||
| Dimensions ( HxWxD ) | 54.1x87.8x52mm | |
| Weight | 0.2kg | |
| Operating Temperature Range | -30-55℃ | |
| Relative Humidity ( noncondensing ) | 5-90% | |
| Mouting Type | DIN-Rail ,35mm | |
Connection

Dimension

Function
| Current AGF-AE-D/100:100A ;AGF-AE-D/200:200A Frequency 60Hz Power Supply(self supply) AC85~265V or DC100~350V; power consumption≤10VA Input consumption less than 0.2VA |
Installation DIN rail 35mm Dimension(L*W*H) 85×54×64mm |
|
Product Data
| Parameters | AGF - AE - D /100 | AGF - AE - D /200 |
| Meter Electrical Service | ||
Rated Voltage - Line to N | 120V | |
| Rated Voltage - Line to Line | 208/240V | |
| Extended Voltage Range | 88%-110% | |
| AC Frequrency | 60Hz | |
| Grids Supported | L1/L2/N/ PE | |
| Power Consumption | 1.2w | |
| communication | ||
| Meter communication interfaces | RS485 | |
| Response Time | ≤1S | |
| Meter Accuracy | ||
| Rated RMS current | 100A | 200A |
| 1%-100% of CT Current | 土0.5% | 土1% |
| Current Transformers | ||
| Number of Supplied Current Transformers | 2 | |
| Dimensions | I . D :15 O . D :35 | 70.5x54.5x39( HxWxD ) mm |
| Standard compliance | ||
| Safety | UL1741 | |
| Installation Specifications | ||
| Dimensions ( HxWxD ) | 54.1x87.8x52mm | |
| Weight | 0.2kg | |
| Operating Temperature Range | -30-55℃ | |
| Relative Humidity ( noncondensing ) | 5-90% | |
| Mouting Type | DIN-Rail ,35mm | |
Connection