All Categories
EN

Home > Products > Energy Meter > IOT Wireless Energy Meter

1 phase AC Smart Electricity Detector Street Lamp Safety Electricity Monitoring 4g Comminocation ARCM310-NK-4G


  • Application:Schools, hospitals, shopping malls, banks, ancient buildings,street lights

  • Rated voltage: AC 220V

  • Current:AC 10 ( 60 ) A

  • Communication:4G

Email: [email protected]

Mobile: +86 134 8217 7205

Whatsapp/Wechat: +86 134 8217 7205

  • Overview
  • Parameter
  • Certificates
  • Customer Questions & Answers
  • Contact us

Overview

ARCM310-NK-4G residual current electrical fire monitoring device is installed in the 0.4kV low-voltage power distribution system, and is used to detect residual current, temperature and other electrical fire hazards in TN-C-S, TN-S and local TT systems.

Parameters, when the parameters of the monitoring device in the protected line exceed the alarm setting value, an alarm and control signal can be generated to eliminate the hidden danger of electrical fire caused by residual current.

The product adopts 4G wireless communication, and can be combined with other monitoring, monitoring units or monitoring hosts to form a fire monitoring system.

The centralized bus-type information management mode or functional partition-type information management mode can be selected according to user needs. It is mostly used in street lights, commercial , buildings and occasions that require detection.

Parameters

project index
Rated voltage Rated value : AC 220V
rated current Rating : AC 10(60) A

Measuring range

electric  current

0.03~60A
residual current 10~300mA
Voltage 130~265V
temperature -10~150℃
monitoring alarm

residual current

20~100 mA continuously adjustable

electric current

Overcurent (20%~120%)
Voltage Overvoltage (100%~120%), undervoltage (80%~100%)
temperature 45~140℃ continuously adjustable
Action delay time 0.1~60S continuously adjustable
measurement accuracy

Frequency 0.05Hz, voltage and curent 0.5 level , active energy 1, other 2

levels

communication 485 communication ; Modbus - RTU protocol
network mode GPRS communication (4G full Netcom )
installation method 35mm guide rail installation
use environment

Working temperature :-10℃~+55℃; relative humidity :≤95%

non - condensing

storage temperature range -20℃~+70℃


Model 

Name Function Description
ARCM310- NK

Real - time monitoring of one - way residual current , two - way temperature , current , voltage , power , electric energy and other electrical parameters ,

RS485communication , with opening and closing control function


ARCM310- NK -4G

Real - time monitoring of one - way residual current ,two - way temperature , current , voltage , power , electric energy and other electrical parameters ,RS485 communication , GPRS wireless communication , with opening and closing control function

Dimensions (in mm) 

image

Figure 1 ARCM310-NK

image

Figure 2 ARCM310-NK-4G

installation

image

35mm guide rail installation, can be fixed by adding fixed terminals.





Parameters

projectindex
Rated voltageRated value : AC 220V
rated currentRating : AC 10(60) A

Measuring range

electric  current

0.03~60A
residual current10~300mA
Voltage130~265V
temperature-10~150℃
monitoring alarm

residual current

20~100 mA continuously adjustable

electric current

Overcurent (20%~120%)
VoltageOvervoltage (100%~120%), undervoltage (80%~100%)
temperature45~140℃ continuously adjustable
Action delay time0.1~60S continuously adjustable
measurement accuracy

Frequency 0.05Hz, voltage and curent 0.5 level , active energy 1, other 2

levels

communication485 communication ; Modbus - RTU protocol
network modeGPRS communication (4G full Netcom )
installation method35mm guide rail installation
use environment

Working temperature :-10℃~+55℃; relative humidity :≤95%

non - condensing

storage temperature range-20℃~+70℃


Customer Questions & Answers