AMC16Z Series AC precision power distribution monitoring device
Monitor the full power parameters of A+B double-way three phase AC incoming circuit
6 way switch state monitoring
2 way alarm output
2 way leakage monitoring
1 way temperature and humidity detection
1 way RS485 communication
Phase-sequence detection
- Overview
- Customer Questions & Answers
- Contact us
Overview
With the rapid development of data center, the energy consumption problem of data center is becoming more and more prominent. The energy management and power supply and distribution design of data center have become a hot issue. Efficient and reliable power distribution system scheme of data center is an effective way to improve the power consumption efficiency of data center and reduce the energy consumption of equipment. In order to realize energy saving in data center, it is necessary to monitor each electrical load first. However, there are many load circuits in data center. Traditional measuring instruments cannot meet the requirements of cost, volume, installation, construction and other aspects. In this case, the multi-circuit monitoring device which is suitable for centralized monitoring in data center is necessary to be used.
AMC16Z series AC precision power distribution monitoring device is specially designed for data center server power management.The device designed exquisite, can provide A + B 2 incoming and 96 outgoing’s electrical parameters, the input and output switch and the state of lightning protection device with real-time monitoring. All alarm threshold of measurement channels can be set in separate. Over-outgoing triggers system acoustooptic warning immediately. Highly integrated monitoring loop is realized in the volume of traditional instruments.
Product Model
Model | Function description |
AMC16Z-ZA | Monitor the full power parameters of A+B double-way three-phase AC incoming circuit, 6-way switch state monitoring, 2-way alarm output, 2-way leakage monitoring, 1-way temperature and humidity detection, 1-way RS485 communication, and phase-sequence detection. |
AMC16Z-FA | Monitor the full power parameters of 24 branches of A+B double-way AC outgoing line, 1-way RS485 communication and phase adjustment. |
AMC16Z-FAK24 | Monitor the full power parameters and switch state of 24 branches of A+B double-way AC outgoing line, 1-way RS485 communication and phase adjustment. |
AMC16Z-FAK48 | Monitor the full power parameters and switch state of 48 branches of A+B double-way AC outgoing line, 1-way RS485 communication and phase adjustment. |
AMC16Z-KA | Wet contact, monitoring A+B total 48 branch switch state, 1-way RS485 communication. |
AMC16Z-KD | Dry contact, monitoring A+B total 48 branch switch state, 1-way RS485 communication. |
AMC16Z-AC220V | AC220V extended power supply, and use when the monitoring circuit is beyond 96 branches of A+B |
Technical parameter