All Categories
EN

Home > Products > Current Transformer > Close Loop Current Transformer

AKH-0.66/I Current Transformer


● Current transformer for measurement

● Suitable for cables or busbar

● Used with energy meters or relays

● 30I, 40I Optional Din Rail Mounted

Email: [email protected]

Mobile: +86 134 8217 7205

Whatsapp/Wechat: +86 134 8217 7205

  • Overview
  • Parameter
  • Certificates
  • Customer Questions & Answers
  • Contact us

Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They are connected with the panel meter or relay and they can help to measure the current or protect the equipment.


Application


6-5

Chemical Factory

6-6

Power Station

6-7

Steel Mill

6-8

Metallurgical Factory


Specification Rated current ratio (A) Precision degree and corresponding rated load (VA) Straight-through tums Bus spec(mm)/number Max. cable outer diameter (mm) Installation
0.2 0.5 1
30I 15/5(1) 1.5 5 / Ф22 A
20/5(1) 1.5 4
25-30/5(1) 1.5 3
40-60/5(1) 1.5 2
75-100/5(1) 1.5 1 30×10/1 A、B
150-200/5(1) 2.5 1
250/5(1) 3.75 1
300-450/5(1) 5 1
500/5(1) 10 1
600/5 10 1
40I 10/5(1) 1.5 10 / Ф30 A
15/5(1) 1.5 8
20/5(1) 1.5 5
25-30/5(1) 1.5 4
40/5(1) 1.5 3
50-75/5(1) 1.5 2
100/5(1) 1.5 1 40×10/1 A、C
150/5(1) 2.5 1
200/5(1) 2.5 1
250/5(1) 3.75 1
300-450/5(1) 5 1
500-800/5(1) 10 1
1000/5(1) 10 1
60I 150/5(1) 2.5 1 60×10/160×6/1-2 Ф44 A、C
200-250/5(1) 2.5 1
300-450/5(1) 5 1
500-800/5(1) 10 1
1000-1250/5(1) 10 1
1500-2000/5(1) 20 1
2500/5(1) 30 1
80I 150/5(1) 2.5 1 80×10/1 Ф50 A、C
200-250/5(1) 2.5 1
300-400/5(1) 5 1
500-800/5(1) 10 1
1000-1250/5(1) 10 1
1500-2000/5(1) 20 1
2500-3000/5(1) 30 1

Characteristics


1-1

● Security factor: FS<5
● Maximum system voltage: 720V AC
●Test voltage: 3kV AC(1min)
●Standards:IEC/EN61869-1, IEC/EN61869-2

1-2

● Rated frequency: 50/60Hz
● Rated short-time thermal current: Ith=40~60In
● Rated dynamic current: Idyn=2.5Ith
● Rated secondary current: X/5A (X/1A upon request)
● Rated primary current: Ranging up to 6000A

1-3

● Continuous overload: 120%In
● Protection level: IP30
● Casing: Non-flammable, polycarbonate self-extinguishing ABS
● Environment:
Operating temperature: -25℃-+50℃
Storage temperature: -40℃-+80℃
Humidity (no condensation) ≤90%RH



Dimension


1-4


Size(mm)   Type Outline size Through size Mounting size Tolerance(mm)
W H D a e Φ M N
30 I 60 78 36 31 11 22 34 57.5 ±1
40 I 75 95 45 40 11 31 40 57.5
60 I 102 130 45 61.5 21 45 42 57.5
80 I 118 140 45 82 11 52 60 57.5


Installation


1-5

TypeA

1-6

TYPE B

1-7

TYPEC

1-8

TYPED


1-9

Type for Din Rail



Wiring


1-10

Application


6-5

Chemical Factory

6-6

Power Station

6-7

Steel Mill

6-8

Metallurgical Factory


SpecificationRated current ratio (A)Precision degree and corresponding rated load (VA)Straight-through tumsBus spec(mm)/numberMax. cable outer diameter (mm)Installation
0.20.51
30I15/5(1)

1.55/Ф22A
20/5(1)

1.54
25-30/5(1)

1.53
40-60/5(1)

1.52
75-100/5(1)

1.5130×10/1A、B
150-200/5(1)
2.5
1
250/5(1)
3.75
1
300-450/5(1)
5
1
500/5(1)
10
1
600/5
10
1
40I10/5(1)

1.510/Ф30A
15/5(1)

1.58
20/5(1)

1.55
25-30/5(1)

1.54
40/5(1)

1.53
50-75/5(1)

1.52
100/5(1)

1.5140×10/1A、C
150/5(1)

2.51
200/5(1)
2.5
1
250/5(1)
3.75
1
300-450/5(1)
5
1
500-800/5(1)
10
1
1000/5(1)10

1
60I150/5(1)

2.5160×10/160×6/1-2Ф44A、C
200-250/5(1)
2.5
1
300-450/5(1)
5
1
500-800/5(1)
10
1
1000-1250/5(1)10

1
1500-2000/5(1)20

1
2500/5(1)30

1
80I150/5(1)

2.5180×10/1Ф50A、C
200-250/5(1)
2.5
1
300-400/5(1)
5
1
500-800/5(1)
10
1
1000-1250/5(1)10

1
1500-2000/5(1)20

1
2500-3000/5(1)30

1
Customer Questions & Answers
  • Question:

    Who are we?

    Answer:

    We are a top manufacturer with over 1500 employees, over 300 R&D engineers in China, with CE, ROHS, IEC, EAC, MID, UL, FCC Certificates, etc. Our Products: AC/DC electricity meters, current transformers, hall sensors, IOT platform, etc. As a top-level provider of electrical solution service, we can help you save energy, reduce cost, improve energy efficiency and safety, realize intelligent, visual and fine management of energy, and provide data services for energy management.

    marry August 23, 2022
  • Answer:

    Always a pre-production sample before mass production; Always final Inspection before shipment;

    marry August 23, 2022
  • Answer:

    AC/DC Energy Meter, Hall Effect Sensor, Current Transformer, Current Transducer, Motor Protectors, Wireless Temperature Monitoring, Residual Current Relay, IOT Platform, etc.

    marry August 23, 2022
  • Answer:

    147 computer software copyrights, 2 million meters, 1.5 million transformers, more than 100 design patents, 70 utility model patents.

    marry August 23, 2022
  • Answer:

    Accepted Delivery Terms: FOB, CFR, CIF, EXW, DDU, Express Delivery, etc. Accepted Payment Currency: USD, EUR, RMB, etc. Accepted Payment Type: T/T, L/C, etc. Language Spoken:English, Spanish, Chinese, etc.

    marry August 23, 2022
Your Name
E-mail *
Phone/Whatsapp
Country
Your identity (dealer or individual)
Your Inquiry *
Clicky