DTSD1352/CT/C 3 Split Core Current Sensors With Modbus RTU RS485 Communication Din Rail Smart Meter


  • Application:PV Solar inverter,AC Energy Monitoring,Industry


  • Rated voltage(AC):3×220/380V, 3×380V, 3×57.7V/100V, 3×100V


  • Reference frequency:50Hz


  • Current Connect:Max 100A Connect/5A


  • Communication:RS485 Communication


Email: [email protected]

Mobile: +86 134 8217 7205

Whatsapp/Wechat: +86 134 8217 7205

  • Overview
  • Parameter
  • Certificates
  • Customer Questions & Answers
  • Contact us

Overview

The DTSD1352-CT/C(ADL3000-E/CTC) kwh meter 3 phase dengan ct is an inverter-connectable smart meter designed for power supply systems, industrial and mining enterprises, and public utilities to calculate electricity consumption and manage electricity demand. It has the characteristics of high precision, small size and simple installation. Provide various data for the past 12 months, check the 31st harmonic content and total harmonic content, realize remote communication and remote control of switch input and relay output, and have the function of alarm output.

Equipped with RS485 communication port, suitable for MODBUS-RTU.DTSD1352-CT/C bi directional meter solar can be used in various control systems, SCADA systems and energy management systems. The instruments all meet the technical requirements for electric energy meters in the IEC62053-21 and IEC62053-22 standards.


Specification

3 phase 3 wires, 3 phase 4 wires

Voltage

Reference voltage

3×100V3×380V3×57.7/100V3×220/380V

Consumption

<10VA(Single phase)

Impedance

>2MΩ

Accuracy class

Error±0.2%

Current

Input current

3×1(6)A3×1(6)A(Outlay transformer)3×10(80)A3×10(100)A(Outlay transformer)

Consumption

<1VA(Single phase rated current)

Accuracy class

Error±0.2%

Power

Active, reactive, apparent power, error±0.5℅

Frequency

4565HzError±0.2%

Temperature

-40℃99℃

Energy

Active energy(Accuracy class:0.5, 1), reactive energy(Accuracy class 2)

Clock

≤0.5s/d

Energy pulse output

1 active optocoupler output, 1 reactive optocoupler output

Switching output

1 Switching output

Switching input

1 optocoupler input

Width of pulse

80±20ms

Pulse constant

6400imp/kWh,400imp/kWh(Correspond with the basic current)

Interface and communication

RS485Modbus RTU

Range of communication address

Modbus RTU:1~ 247

Baud rate

1200bps~19200bps

Relative temperature

-25℃~+55℃

Relative humidity

≤95℅(No condensation)





image


DTSD1352/CTC 3 phase power meter data logger

AC3*220/380V、3*380V、3*57.7/100V、3*100V 3*10 (100) A
U、I、P、Q、S、PF、KWH、KVARH
RS485 (MODBUS-RTU)
LCD Display

Frozen Data
2-31th Harmonic Measurement
KWH Accuracy 0.5S,KVARH Accuracy 2


Parameters

Wiring:3P3W/3P4W
Accuracy:Active Energy 0.5S,Negtive Energy 2
Voltage:3x57.7V/100V 3x380V 3x100V


Current:3x10(100)A

Com Interface:2-Ways RS485 COM Interface (Optional),l Infrared COM Interface
Protocol:Modbus DL/T645
Dimension:126.5*88*69.5mm
image



Dimension

image

image


Other Models

Shape Model Function Optional function

image

DTSD1352/C


Wiring:3P3W/3P4W

Voltage:3x57.7V/100V 3x380V 3x100V

Current:Under 80A direct connect,

more than 80A via 5A ct connect

Communication:RS485


1.RS485-MODBUS(C) 2.Multi-Tariff(F) 3.1DI1DO(K)orsecond road RS485 4.2-31 harmonic&THD(H)

image

DTSD1352-CTC

Wiring:3P3W/3P4W

Voltage:3x57.7V/100V 3x380V 3x100V

Current:with 3 pcs 100A cts

Communication:RS485


3 and 4 cannot be selected together


Specification

3 phase 3 wires, 3 phase 4 wires

Voltage

Reference voltage

3×100V3×380V3×57.7/100V3×220/380V

Consumption

<10VA(Single phase)

Impedance

>2MΩ

Accuracy class

Error±0.2%

Current

Input current

3×1(6)A3×1(6)A(Outlay transformer)3×10(80)A3×10(100)A(Outlay transformer)

Consumption

<1VA(Single phase rated current)

Accuracy class

Error±0.2%

Power

Active, reactive, apparent power, error±0.5℅

Frequency

4565HzError±0.2%

Temperature

-40℃99℃

Energy

Active energy(Accuracy class:0.5, 1), reactive energy(Accuracy class 2)

Clock

≤0.5s/d

Energy pulse output

1 active optocoupler output, 1 reactive optocoupler output

Switching output

1 Switching output

Switching input

1 optocoupler input

Width of pulse

80±20ms

Pulse constant

6400imp/kWh,400imp/kWh(Correspond with the basic current)

Interface and communication

RS485Modbus RTU

Range of communication address

Modbus RTU:1~ 247

Baud rate

1200bps~19200bps

Relative temperature

-25℃~+55℃

Relative humidity

≤95℅(No condensation)